Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.692
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732804

RESUMO

In general, it is difficult to visualize internal ocular structure and detect a lesion such as a cataract or glaucoma using the current ultrasound brightness-mode (B-mode) imaging. This is because the internal structure of the eye is rich in moisture, resulting in a lack of contrast between tissues in the B-mode image, and the penetration depth is low due to the attenuation of the ultrasound wave. In this study, the entire internal ocular structure of a bovine eye was visualized in an ex vivo environment using the compound acoustic radiation force impulse (CARFI) imaging scheme based on the phase-inverted ultrasound transducer (PIUT). In the proposed method, the aperture of the PIUT is divided into four sections, and the PIUT is driven by the out-of-phase input signal capable of generating split-focusing at the same time. Subsequently, the compound imaging technique was employed to increase signal-to-noise ratio (SNR) and to reduce displacement error. The experimental results demonstrated that the proposed technique could provide an acoustic radiation force impulse (ARFI) image of the bovine eye with a broader depth-of-field (DOF) and about 80% increased SNR compared to the conventional ARFI image obtained using the in-phase input signal. Therefore, the proposed technique can be one of the useful techniques capable of providing the image of the entire ocular structure to diagnose various eye diseases.


Assuntos
Técnicas de Imagem por Elasticidade , Olho , Razão Sinal-Ruído , Transdutores , Animais , Bovinos , Olho/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia/métodos
2.
Gynecol Endocrinol ; 40(1): 2352139, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38733361

RESUMO

OBJECTIVE: The main purpose of this systematic review and meta-analysis was to investigate the diagnostic value of ultrasound elastography in the evaluation of polycystic ovary syndrome (PCOS). METHODS: A comprehensive and methodical investigation was carried out in the databases of PubMed, EMBASE, Cochrane, Scopus, Web of Science, and China National Knowledge Infrastructure, covering the entire duration of these databases until October 18, 2023. The primary purpose of this research was to evaluate and contrast ovarian tissue elasticity in people with and without PCOS. The elasticity of ovarian tissue was quantified using standardized mean difference (SMD). RESULTS: A total of eight studies were ultimately selected for systematic evaluation and meta-analysis. Five studies used shear wave elastography (SWE) as a diagnostic tool, and it was discovered that women with PCOS had higher levels of ovarian shear wave elasticity than their healthy counterparts. The SMD was determined to be 1.86 kilopascal (95% CI: 1.27 to 2.44). Three studies were conducted using strain elastography (SE) to compare the ovarian strain ratio of patients with PCOS to that of a healthy control group. The SMD for the PCOS group was 2.07 (95% CI: 1.79 to 2.34), which indicated that the ovarian strain ratio was significantly higher in that group. CONCLUSION: This systematic review and meta-analysis found that women with PCOS had stiffer ovarian tissue than women without the disorder. Ultrasound elastography may provide clinicians with value beyond 2D ultrasound in the diagnosis of PCOS.


Assuntos
Técnicas de Imagem por Elasticidade , Síndrome do Ovário Policístico , Síndrome do Ovário Policístico/diagnóstico por imagem , Síndrome do Ovário Policístico/fisiopatologia , Humanos , Técnicas de Imagem por Elasticidade/métodos , Feminino , Ovário/diagnóstico por imagem , Elasticidade
3.
Medicine (Baltimore) ; 103(19): e38035, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728451

RESUMO

OBJECTIVE: The objective of this meta-analysis is to evaluate the diagnostic performance of acoustic radiation force impulse (ARFI) in acute pancreatitis (AP) patients. METHODS: PubMed, Web of Science, Embase, Wanfang, Chinese Biological Medicine databases, and Chinese Biomedical Literature Service System were searched for relevant studies to explore the potential diagnostic performance of ARFI in AP from inception to November 2023. STATA 14.0 was used to analyze the standardized mean difference (SMD) with 95% confidence interval (CI), pooled sensitivity, specificity, area under the curve, meta-regression analysis, sensitivity analysis, and publication bias. RESULTS: Nine studies, involving 533 AP patients and 585 healthy controls, were included. AP patients had significantly higher ARFI levels than healthy controls (SMD: 3.13, 95% CI: 1.88-4.39, P = .001). The area under the curve of ARFI for diagnosing AP was 0.99 (95% CI: 0.98-1.00), with 98% sensitivity and 94% specificity. Meta-regression identified the study region and study period as the sources of heterogeneity. Sensitivity analysis showed that the exclusion of any single study did not materially alter the overall combined effect. No evidence of publication bias was observed in the included studies. CONCLUSION: This meta-analysis demonstrated that ARFI exerted satisfactory diagnostic performance in AP.


Assuntos
Técnicas de Imagem por Elasticidade , Pancreatite , Sensibilidade e Especificidade , Humanos , Pancreatite/diagnóstico , Pancreatite/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Doença Aguda
4.
BMC Cancer ; 24(1): 409, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566057

RESUMO

BACKGROUND: Accurate evaluation of axillary lymph node metastasis (LNM) in breast cancer is very important. A large number of hyperplastic and dilated lymphangiogenesis cases can usually be found in the pericancerous tissue of breast cancer to promote the occurrence of tumor metastasis.Shear wave elastography (SWE) can be used as an important means for evaluating pericancerous stiffness. We determined the stiffness of the pericancerous by SWE to diagnose LNM and lymphangiogenesis in invasive breast cancer (IBC). METHODS: Patients with clinical T1-T2 stage IBC who received surgical treatment in our hospital from June 2020 to December 2020 were retrospectively enrolled. A total of 299 patients were eventually included in the preliminary study, which included an investigation of clinicopathological features, ultrasonic characteristics, and SWE parameters. Multivariable logistic regression analysis was used to establish diagnostic model and evaluated its diagnostic performance of LNM. The correlation among SWE values, collagen volume fraction (CVF), and microlymphatic density (MLD) in primary breast cancer lesions was analyzed in another 97 patients. RESULTS: The logistic regression model is Logit(P)=-1.878 + 0.992*LVI-2.010*posterior feature enhancement + 1.230*posterior feature shadowing + 0.102*posterior feature combined pattern + 0.009*Emax. The optimum cutoff value of the logistic regression model was 0.365, and the AUC (95% CI) was 0.697 (0.636-0.758); the sensitivity (70.7 vs. 54.3), positive predictive value (PPV) (54.0 vs. 50.8), negative predictive value (NPV) (76.9 vs. 69.7), and accuracy (65.2 vs. 61.9) were all higher than Emax. There was no correlation between the SWE parameters and MLD in primary breast cancer lesions. CONCLUSIONS: The logistic regression model can help us to determine LNM, thus providing more imaging basis for the selection of preoperative treatment. The SWE parameter of the primary breast cancer lesion cannot reflect the peritumoral lymphangiogenesis, and we still need to find a new ultrasonic imaging method.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Linfangiogênese , Metástase Linfática/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos
5.
Hong Kong Med J ; 30(2): 110-119, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38651202

RESUMO

INTRODUCTION: Methotrexate (MTX) is effective for treating psoriasis and psoriatic arthritis, but its potential hepatoxicity remains a concern. Liver biopsy, the gold standard for detecting MTX-induced liver injury, is invasive and carries considerable risk. Transient elastography (TE) offers a non-invasive alternative for detecting advanced liver fibrosis. This study investigated the performance of TE in detecting MTX-induced liver fibrosis among Chinese psoriasis patients, compared with liver biopsy. METHODS: This study included adult patients with clinical psoriasis. Liver stiffness measurement using TE was performed in patients receiving MTX. Exclusion criteria were known liver cirrhosis, positive viral hepatitis carrier status, or conditions influencing TE performance. Liver biopsy was performed when liver stiffness was ≥7.1 kilopascals (kPa) or when the total cumulative dose (TCD) of MTX was ≥3.5 g. RESULTS: A total of 228 patients were screened; among 34 patients who met the inclusion criteria, nine (26.5%) had significant liver fibrosis (Roenigk grade ≥3a). The area under the receiver operating characteristic curve was 0.76 (95% confidence interval=0.59-0.93; P=0.021), indicating that TE had satisfactory performance in detecting liver fibrosis. A cut-off value of 7.1 kPa of liver stiffness yielded 100% sensitivity and 68% specificity. Liver fibrosis was not correlated with the TCD of MTX or the duration of MTX use; it was significantly correlated with obesity and diabetes status (body mass index ≥30 kg/m2, waist circumference ≥138 cm, and glycated haemoglobin level ≥7.8%). CONCLUSION: Transient elastography is reliable and superior to the TCD for detecting liver fibrosis in Chinese psoriasis patients receiving MTX. Liver biopsy should be reserved for high-risk patients or patients with liver stiffness ≥11.7 kPa on TE.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Metotrexato , Psoríase , Humanos , Técnicas de Imagem por Elasticidade/métodos , Metotrexato/efeitos adversos , Metotrexato/uso terapêutico , Metotrexato/administração & dosagem , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Masculino , Psoríase/tratamento farmacológico , Psoríase/complicações , Psoríase/patologia , Feminino , Pessoa de Meia-Idade , Adulto , Fígado/patologia , Fígado/diagnóstico por imagem , Biópsia , Curva ROC , Fármacos Dermatológicos/uso terapêutico , Fármacos Dermatológicos/efeitos adversos , Fármacos Dermatológicos/administração & dosagem , Idoso , População do Leste Asiático
6.
Curr Opin Obstet Gynecol ; 36(3): 181-185, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38656810

RESUMO

PURPOSE OF REVIEW: This article reviews recent advances in ultrasound elastography in diagnosing and evaluating the normal nongravid uterus and the infertile uterus in the gynecologic patient. RECENT FINDINGS: Focusing on the most recent primary literature, studies have demonstrated new findings among a breadth of gynecologic clinical settings. Studies in the nongravid uterus have found that menopausal status, age, and menstrual phase have not been associated with changes in uterine tissue stiffness. Focusing on myometrial disease, there have been conflicting data regarding the ability to distinguish uterine fibroids from adenomyosis. One area of expanding research surrounding uterine elastography includes the infertile population, where ongoing studies attempt to provide a predictive model using shear wave elastography (SWE) in patients undergoing in-vitro fertilization. SUMMARY: Ultrasound elastography has become an increasingly studied and utilized tool in assessing physiologic and pathologic processes in the field of gynecology. Evaluating tissue stiffness through strain and SWE can serve to improve diagnosis of various uterine and cervical lesions, as well as prognosticate outcomes after fertility treatments. This growing area of research will continue to establish the role and application of ultrasound elastography into clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade , Infertilidade Feminina , Útero , Humanos , Feminino , Técnicas de Imagem por Elasticidade/métodos , Útero/diagnóstico por imagem , Infertilidade Feminina/diagnóstico por imagem , Leiomioma/diagnóstico por imagem , Doenças Uterinas/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Adenomiose/diagnóstico por imagem
7.
Radiology ; 311(1): e231461, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38652028

RESUMO

Background Noninvasive tests can be used to screen patients with chronic liver disease for advanced liver fibrosis; however, the use of single tests may not be adequate. Purpose To construct sequential clinical algorithms that include a US deep learning (DL) model and compare their ability to predict advanced liver fibrosis with that of other noninvasive tests. Materials and Methods This retrospective study included adult patients with a history of chronic liver disease or unexplained abnormal liver function test results who underwent B-mode US of the liver between January 2014 and September 2022 at three health care facilities. A US-based DL network (FIB-Net) was trained on US images to predict whether the shear-wave elastography (SWE) value was 8.7 kPa or higher, indicative of advanced fibrosis. In the internal and external test sets, a two-step algorithm (Two-step#1) using the Fibrosis-4 Index (FIB-4) followed by FIB-Net and a three-step algorithm (Three-step#1) using FIB-4 followed by FIB-Net and SWE were used to simulate screening scenarios where liver stiffness measurements were not or were available, respectively. Measures of diagnostic accuracy were calculated using liver biopsy as the reference standard and compared between FIB-4, SWE, FIB-Net, and European Association for the Study of the Liver guidelines (ie, FIB-4 followed by SWE), along with sequential algorithms. Results The training, validation, and test data sets included 3067 (median age, 42 years [IQR, 33-53 years]; 2083 male), 1599 (median age, 41 years [IQR, 33-51 years]; 1124 male), and 1228 (median age, 44 years [IQR, 33-55 years]; 741 male) patients, respectively. FIB-Net obtained a noninferior specificity with a margin of 5% (P < .001) compared with SWE (80% vs 82%). The Two-step#1 algorithm showed higher specificity and positive predictive value (PPV) than FIB-4 (specificity, 79% vs 57%; PPV, 44% vs 32%) while reducing unnecessary referrals by 42%. The Three-step#1 algorithm had higher specificity and PPV compared with European Association for the Study of the Liver guidelines (specificity, 94% vs 88%; PPV, 73% vs 64%) while reducing unnecessary referrals by 35%. Conclusion A sequential algorithm combining FIB-4 and a US DL model showed higher diagnostic accuracy and improved referral management for all-cause advanced liver fibrosis compared with FIB-4 or the DL model alone. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Ghosh in this issue.


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade , Cirrose Hepática , Humanos , Masculino , Cirrose Hepática/diagnóstico por imagem , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Técnicas de Imagem por Elasticidade/métodos , Adulto , Aprendizado Profundo , Fígado/diagnóstico por imagem , Fígado/patologia , Idoso , Ultrassonografia/métodos
8.
Ultrasonics ; 140: 107312, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38599075

RESUMO

BACKGROUND: Shear wave elastography (SWE) is mainly used for stiffness estimation of large, homogeneous tissues, such as the liver and breasts. However, little is known about its accuracy and applicability in thin (∼0.5-2 mm) vessel walls. To identify possible performance differences among vendors, we quantified differences in measured wave velocities obtained by commercial SWE implementations of various vendors over different imaging depths in a vessel-mimicking phantom. For reference, we measured SWE values in the cylindrical inclusions and homogeneous background of a commercial SWE phantom. Additionally, we compared the accuracy between a research implementation and the commercially available clinical SWE on an Aixplorer ultrasound system in phantoms and in vivo in patients. METHODS: SWE measurements were performed over varying depths (0-35 mm) using three ultrasound machines with four ultrasound probes in the homogeneous 20 kPa background and cylindrical targets of 10, 40, and 60 kPa of a multi-purpose phantom (CIRS-040GSE) and in the anterior and posterior wall of a homogeneous polyvinyl alcohol vessel-mimicking phantom. These phantom data, along with in vivo SWE data of carotid arteries in 23 patients with a (prior) head and neck neoplasm, were also acquired in the research and clinical mode of the Aixplorer ultrasound machine. Machine-specific estimated phantom stiffness values (CIRS phantom) or wave velocities (vessel phantom) over all depths were visualized, and the relative error to the reference values and inter-frame variability (interquartile range/median) were calculated. Correlations between SWE values and target/vessel wall depth were explored in phantoms and in vivo using Spearman's correlations. Differences in wave velocities between the anterior and posterior arterial wall were assessed with Wilcoxon signed-rank tests. Intra-class correlation coefficients were calculated for a sample of ten patients as a measure of intra- and interobserver reproducibility of SWE analyses in research and clinical mode. RESULTS: There was a high variability in obtained SWE values among ultrasound machines, probes, and, in some cases, with depth. Compared to the homogeneous CIRS-background, this variation was more pronounced for the inclusions and the vessel-mimicking phantom. Furthermore, higher stiffnesses were generally underestimated. In the vessel-mimicking phantom, anterior wave velocities were (incorrectly) higher than posterior wave velocities (3.4-5.6 m/s versus 2.9-5.9 m/s, p ≤ 0.005 for 3/4 probes) and remarkably correlated with measurement depth for most machines (Spearman's ρ = -0.873-0.969, p < 0.001 for 3/4 probes). In the Aixplorer's research mode, this difference was smaller (3.3-3.9 m/s versus 3.2-3.6 m/s, p = 0.005) and values did not correlate with measurement depth (Spearman's ρ = 0.039-0.659, p ≥ 0.002). In vivo, wave velocities were higher in the posterior than the anterior vessel wall in research (left p = 0.001, right p < 0.001) but not in clinical mode (left: p = 0.114, right: p = 0.483). Yet, wave velocities correlated with vessel wall depth in clinical (Spearman's ρ = 0.574-0.698, p < 0.001) but not in research mode (Spearman's ρ = -0.080-0.466, p ≥ 0.003). CONCLUSIONS: We observed more variation in SWE values among ultrasound machines and probes in tissue with high stiffness and thin-walled geometry than in low stiffness, homogeneous tissue. Together with a depth-correlation in some machines, where carotid arteries have a fixed location, this calls for caution in interpreting SWE results in clinical practice for vascular applications.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Desenho de Equipamento , Adulto
9.
World J Gastroenterol ; 30(10): 1450-1460, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38596502

RESUMO

BACKGROUND: Direct-acting antiviral agents (DAAs) are highly effective treatment for chronic hepatitis C (CHC) with a significant rate of sustained virologic response (SVR). The achievement of SVR is crucial to prevent additional liver damage and slow down fibrosis progression. The assessment of fibrosis degree can be performed with transient elastography, magnetic resonance elastography or shear-wave elastography (SWE). Liver elastography could function as a predictor for hepatocellular carcinoma (HCC) in CHC patients treated with DAAs. AIM: To explore the predictive value of SWE for HCC development after complete clearance of hepatitis C virus (HCV). METHODS: A comprehensive literature search of clinical studies was performed to identify the ability of SWE to predict HCC occurrence after HCV clearance. In accordance with the study protocol, a qualitative and quantitative analysis of the evidence was planned. RESULTS: At baseline and after 12 wk of follow-up, a trend was shown towards greater liver stiffness (LS) in those who go on to develop HCC compared to those who do not [baseline LS standardized mean difference (SMD): 1.15, 95% confidence interval (95%CI): 020-2.50; LS SMD after 12 wk: 0.83, 95%CI: 0.33-1.98]. The absence of a statistically significant difference between the mean LS in those who developed HCC or not may be related to the inability to correct for confounding factors and the absence of raw source data. There was a statistically significant LS SMD at 24 wk of follow-up between patients who developed HCC vs not (0.64; 95%CI: 0.04-1.24). CONCLUSION: SWE could be a promising tool for prediction of HCC occurrence in patients treated with DAAs. Further studies with larger cohorts and standardized timing of elastographic evaluation are needed to confirm these data.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Hepatite C Crônica , Hepatite C , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/etiologia , Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/etiologia , Neoplasias Hepáticas/tratamento farmacológico , Hepacivirus , Técnicas de Imagem por Elasticidade/métodos , Antivirais/uso terapêutico , Hepatite C Crônica/complicações , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/tratamento farmacológico , Resposta Viral Sustentada , Fibrose , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/tratamento farmacológico , Hepatite C/tratamento farmacológico
10.
Hepatol Commun ; 8(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38517204

RESUMO

BACKGROUND: As the prevalence of metabolic dysfunction-associated steatotic liver disease increases, it is imperative to have noninvasive alternatives to liver biopsy. Velacur offers a non-invasive, point-of-care ultrasound-based method for the assessment of liver stiffness and attenuation. The aim of this study was to perform a head-to-head comparison of liver stiffness and liver fat determined by Velacur and FibroScan using MRI-based measurements as the reference standard. METHODS: This prospective cross-sectional study included 164 adult participants with well-characterized metabolic dysfunction-associated steatotic liver disease. Patients underwent a research exam including Velacur, FibroScan and contemporaneous magnetic resonance elastography, and magnetic resonance imaging proton density fat fraction (MRI-PDFF) scans. The primary outcome was the presence of advanced fibrosis (>F2) as measured by magnetic resonance elastography and the presence of liver fat (>5%) as measured by MRI-PDFF. RESULTS: The mean age and body mass index were 57±12 years and 30.6±4.8 kg/m2, respectively. The mean liver stiffness on magnetic resonance elastography was 3.22±1.39 kPa and the mean liver fat on MRI-PDFF was 14.2±8%. The liver stiffness assessments by Velacur and FibroScan were similar for the detection of advanced fibrosis (AUC 0.95 vs. 0.97) and were not statistically different (p=0.43). Velacur was significantly better than FibroScan (AUC 0.94 vs. 0.79, p=0.01), for the detection of MRI-PDFF >5% (diagnosis of metabolic dysfunction-associated liver disease). CONCLUSIONS: Velacur was superior to FibroScan for liver fat detection with MRI-PDFF as the reference. Velacur and FibroScan were not statistically different for liver stiffness assessment as defined by magnetic resonance elastography.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Adulto , Humanos , Estudos Transversais , Técnicas de Imagem por Elasticidade/métodos , Fibrose , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Estudos Prospectivos
11.
Curr Opin Gastroenterol ; 40(3): 148-155, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38547334

RESUMO

PURPOSE OF REVIEW: The result of ongoing liver injury - and disease, regardless of cause - is fibrosis, and fibrosis appears to be a critically important result of ongoing injury. Further, in a number of different liver diseases, the presence of fibrosis has prognostic value. Therefore, the assessment of fibrosis is of critical clinical importance. Given the importance of fibrosis, there has been a rapid evolution in the use of noninvasive liver tests. This review highlights a number of the core principles surrounding. RECENT FINDINGS: The use of noninvasive test has progressed rapidly over the last decade and data are rapidly accumulating. New terminology has been adapted by the American Association for the Study of Liver Disease (AASLD) for noninvasive assessment of liver disease and termed 'NILDA' (Non-Invasive Liver Disease Assessment). Blood based such as APRI and or FIB-4 and imaging tests such as liver stiffness measurement (LSM) have moderate to high degrees of accuracy for detection of advanced liver fibrosis (≥ F2) and even higher accuracy for detection of severe fibrosis (F4 or cirrhosis). NILDA are particularly effective at the ends of the liver disease spectrum. For example, a very low LSM (less than 7 kPa) essentially excludes significant fibrosis or portal hypertension, and a very high LSM (> 25 kPa) makes significant fibrosis with portal hypertension (cirrhosis) highly likely. SUMMARY: NILDA are currently front and center in terms of assessment of the severity of liver disease. In all patients with known or suspected liver disease, noninvasive blood tests, including APRI and or FIB-4, should be the initial choice to assess the severity of liver fibrosis and/or portal hypertension. In most patients, these tests should be followed with imaging evaluation. The most commonly available imaging is LSM, which appears to be more accurate in predicting fibrosis severity, and is superior to blood tests in the assessment of portal hypertension. In situations in which there is diagnostic uncertainly, liver biopsy with or without HVPG remains an important consideration.


Assuntos
Técnicas de Imagem por Elasticidade , Hipertensão Portal , Humanos , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Fígado/diagnóstico por imagem , Fígado/patologia , Hipertensão Portal/diagnóstico , Hipertensão Portal/etiologia , Prognóstico , Fibrose
12.
Sci Rep ; 14(1): 7452, 2024 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-38548875

RESUMO

Identifying effective, feasible, low-cost interventions that promote sustainable lifestyle changes in nonalcoholic fatty liver disease (NAFLD) is a key unmet need. The aim of this study was to assess predictors of lifestyle practice patterns of NAFLD patients and evaluate the implementation of a mobile technology-based intervention. We prospectively enrolled adults with NAFLD (diagnosed by imaging or biopsy). Individuals with additional liver diseases or decompensated cirrhosis were excluded. Patient were randomized to usual care or a FitBit based program for 6-months. We obtained anthropometrics, labs, vibration controlled transient elastography (VCTE), health-related quality of life (HRQOL), physical activity, diet and motivation to change data. 70 patients were enrolled, 33% with cirrhosis. Median age was 52.1 years, 47% males, 83% white, body mass index 32.3, liver stiffness 7.6 kPa, controlled attenuation parameter 319 db/m, and 50% had diabetes. Baseline HRQOL was 5.4/7 and independently negatively correlated with level of concern about their disease and positively with physical function. Younger age was independently associated with unhealthy diets whereas diabetes was independently associated with unhealthy diets and higher VCTE kPa. 6-month follow-up data available on 31 patients showed trends in improvement in weight. In a cohort of NAFLD patients, we identified independent correlates of lifestyle behaviors and HRQOL. Implementation of interventions that improve physical function may improve HRQOL in NAFLD. Younger patients and those with diabetes appeared to have the greatest need for dietary interventions. Structured mobile technology lifestyle interventions using Fitbit and personalized coaching showed promise but require further validation with a focus on sustainability of intervention and improvement in outcomes.


Assuntos
Diabetes Mellitus , Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Hepatopatia Gordurosa não Alcoólica/complicações , Qualidade de Vida , Cirrose Hepática/patologia , Técnicas de Imagem por Elasticidade/métodos , Estilo de Vida , Diabetes Mellitus/patologia , Fígado/patologia
13.
Nagoya J Med Sci ; 86(1): 104-109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38505715

RESUMO

Prostaglandin E1 intracavernous injection test is an established method for diagnosing erectile dysfunction. However, the evaluation is non-objective and often influenced by the evaluator's subjectivity. Herein, we measured and objectively evaluated shear wave elastography results of the corpus cavernosum before and after injection in 16 patients who underwent prostaglandin E1 testing. The response score of prostaglandin E1 tests were "1" in 2 cases, "2" in 2 cases, and "3" in 12 cases. The average transmission velocity before the injection and at the time of maximum erection after the injection were 2.21 m/s and 1.57 m/s, respectively. Transmission velocity decreased during erection in 14 of 16 cases (87.5%). The overall rate of change in transmission velocity due to injection was -26.7% and was significantly different between the poor (responses 1 and 2: -16.1%) and good erection (response 3: -30.2%) groups. To the best of our knowledge, this is the first attempt to evaluate erectile phenomenon using percutaneous ultrasonic elastography in Japan. Rate of change in shear wave transmission velocity due to prostaglandin E1 injection in the corpus cavernosum penis was associated with the degree of erection. Therefore, the rate of change in shear wave transmission velocity in the corpus cavernosum penis could be used as an objective index of erectile phenomenon. Percutaneous ultrasonic elastography is a non-invasive and useful test method for diagnosing erectile dysfunction, determining the therapeutic effect, and predicting prognosis.


Assuntos
Técnicas de Imagem por Elasticidade , Disfunção Erétil , Masculino , Humanos , Disfunção Erétil/diagnóstico por imagem , Disfunção Erétil/tratamento farmacológico , Alprostadil/uso terapêutico , Técnicas de Imagem por Elasticidade/métodos , Ereção Peniana/fisiologia , Pênis/diagnóstico por imagem
14.
Sci Rep ; 14(1): 7180, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531932

RESUMO

We aimed to investigate the correlation between shear-wave elastography (SWE) and apparent diffusion coefficient (ADC) values in breast cancer and to identify the associated characteristics. We included 91 breast cancer patients who underwent SWE and breast MRI prior to surgery between January 2016 and November 2017. We measured the lesion's mean (Emean) and maximum (Emax) elasticities of SWE and ADC values. We evaluated the correlation between SWE, ADC values and tumor size. The mean SWE and ADC values were compared for categorical variable of the pathological/imaging characteristics. ADC values showed negative correlation with Emean (r = - 0.315, p = 0.002) and Emax (r = - 0.326, p = 0.002). SWE was positively correlated with tumor size (r = 0.343-0.366, p < 0.001). A higher SWE value indicated a tendency towards a higher T stage (p < 0.001). Triple-negative breast cancer showed the highest SWE values (p = 0.02). SWE were significantly higher in breast cancers with posterior enhancement, vascularity, and washout kinetics (p < 0.02). SWE stiffness and ADC values were negatively correlated in breast cancer. SWE values correlated significantly with tumor size, and were higher in triple-negative subtype and aggressive imaging characteristics.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Neoplasias Mamárias Animais , Neoplasias de Mama Triplo Negativas , Humanos , Animais , Feminino , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Mama/patologia , Ultrassonografia Mamária/métodos
15.
Magn Reson Imaging ; 109: 173-179, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38484948

RESUMO

BACKGROUND: Increasing evidence has indicated that high tissue stiffness (TS) may be a potential biomarker for evaluation of tumor aggressiveness. PURPOSE: To investigate the value of magnetic resonance elastography (MRE)-based quantitative parameters preoperatively predicting the tumor grade and subtype of cervical cancer (CC). STUDY TYPE: Retrospective. POPULATION: Twenty-five histopathology-proven CC patients and 7 healthy participants. FIELD STRENGTH/SEQUENCE: 3.0T, magnetic resonance imaging (MRI) (LAVA-flex) and MRE with a three-dimensional spin-echo echo-planar imaging. ASSESSMENT: The regions of interest (ROIs) were manually drawn by two observers in tumors to measure mean TS, storage modulus (G'), loss modulus (G″) and damping ratio (DR) values. Surgical specimens were evaluated for tumor grades and subtypes. STATISTICAL TESTS: Intraclass correlation coefficient (ICC) was expressed in terms of inter-observer agreements. t-test or Mann-Whitney nonparametric test was used to compare the complex modulus and apparent diffusion coefficient (ADC) values between different tumor groups. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic performance. RESULTS: The TS of endocervical adenocarcinoma (ECA) group was significantly higher than that in squamous cell carcinoma (SCC) group (5.27 kPa vs. 3.44 kPa, P = 0.042). The TS also showed significant difference between poorly and well/moderately differentiated CC (5.21 kPa vs. 3.47 kPa, P = 0.038), CC patients and healthy participants (4.18 kPa vs. 1.99 kPa, P < 0.001). The cutoff value of TS to discriminate ECA from SCC was 4.10 kPa (AUC: 0.80), while it was 4.42 kPa to discriminate poorly from well/moderately differentiated CC (AUC: 0.83), and 2.25 kPa to distinguish normal cervix from CC (AUC: 0.88), respectively. There were no significant difference in G″, DR and ADC values between any subgroups except for comparison of healthy participants and CC patients (P = 0.001, P = 0.004, P < 0.001, respectively). DATA CONCLUSION: 3D MRE-assessed TS shows promise as a potential biomarker to preoperatively assess tumor grade and subtype of CC.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias do Colo do Útero , Feminino , Humanos , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos , Neoplasias do Colo do Útero/diagnóstico por imagem , Imageamento por Ressonância Magnética , Biomarcadores
16.
Magn Reson Imaging ; 109: 127-133, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38513784

RESUMO

PURPOSE: Magnetic resonance elastography (MRE) is a noninvasive tool for diagnosing hepatic fibrosis with high accuracy. We investigated the preoperative clinical and imaging predictors of intrahepatic recurrence after curative resection of hepatocellular carcinoma (HCC), and evaluated MRE as a predictor of intrahepatic recurrence. METHODS: We retrospectively evaluated 80 patients who underwent preoperative contrast-enhanced magnetic resonance imaging (MRI) with two-dimensional MRE and curative resection for treatment-naïve HCC between May 2019 and December 2021. Liver stiffness (LS) was measured on the elastograms, and the optimal cutoff of LS for predicting intrahepatic recurrence was obtained using receiver operating characteristic (ROC) analysis. An LS above this cutoff was defined as MRE-recurrence. Preoperative imaging features of the tumor were assessed on MRI, including features in the Liver Imaging Reporting and Data System and microvascular invasion (MVI). Recurrence-free survival (RFS) rates were estimated using the Kaplan-Meier method, and differences were compared using the log-rank test. Using a Cox proportional hazards model, we conducted a multivariable analysis to investigate the factors affecting recurrence-free survival. RESULTS: During a median follow-up period of 32 months (range, 4-52 months), thirteen patients (16.3%) developed intrahepatic recurrence. ROC analysis determined an LS cutoff of ≥4.35 kPa to define MRE-recurrence. The 4-year RFS rate was significantly higher in patients without MRE-recurrence than in those with MRE-recurrence (93.4% vs. 48.9%; p = 0.001). In multivariable analysis, MRE-recurrence (Hazard ratio [HR], 5.9; 95% confidence interval [CI], 1.5-23.1) and MVI (HR, 3.4; 95% CI, 1.0-11.3) were independent predictors of intrahepatic recurrence. CONCLUSIONS: Patients without MRE-recurrence had significantly higher RFS rates than those with MRE-recurrence. MRE-recurrence and MVI were independent predictors of intrahepatic recurrence in patients after curative resection for HCC.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos
17.
JAMA ; 331(15): 1287-1297, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38512249

RESUMO

Importance: Metabolic dysfunction-associated steatotic liver disease (MASLD) is currently the most common chronic liver disease worldwide. It is important to develop noninvasive tests to assess the disease severity and prognosis. Objective: To study the prognostic implications of baseline levels and dynamic changes of the vibration-controlled transient elastography (VCTE)-based scores developed for the diagnosis of advanced fibrosis (Agile 3+) and cirrhosis (Agile 4) in patients with MASLD. Design, Setting, and Participants: This cohort study included data from a natural history cohort of patients with MASLD who underwent VCTE examination at 16 tertiary referral centers in the US, Europe, and Asia from February 2004 to January 2023, of which the data were collected prospectively at 14 centers. Eligible patients were adults aged at least 18 years with hepatic steatosis diagnosed by histologic methods (steatosis in ≥5% of hepatocytes) or imaging studies (ultrasonography, computed tomography or magnetic resonance imaging, or controlled attenuation parameter ≥248 dB/m by VCTE). Main Outcomes and Measures: The primary outcome was liver-related events (LREs), defined as hepatocellular carcinoma or hepatic decompensation (ascites, variceal hemorrhage, hepatic encephalopathy, or hepatorenal syndrome), liver transplant, and liver-related deaths. The Agile scores were compared with histologic and 8 other noninvasive tests. Results: A total of 16 603 patients underwent VCTE examination at baseline (mean [SD] age, 52.5 [13.7] years; 9600 [57.8%] were male). At a median follow-up of 51.7 (IQR, 25.2-85.2) months, 316 patients (1.9%) developed LREs. Both Agile 3+ and Agile 4 scores classified fewer patients between the low and high cutoffs than most fibrosis scores and achieved the highest discriminatory power in predicting LREs (integrated area under the time-dependent receiver-operating characteristic curve, 0.89). A total of 10 920 patients (65.8%) had repeated VCTE examination at a median interval of 15 (IQR, 11.3-27.7) months and were included in the serial analysis. A total of 81.9% of patients (7208 of 8810) had stable Agile 3+ scores and 92.6% of patients (8163 of 8810) had stable Agile 4 scores (same risk categories at both assessments). The incidence of LREs was 0.6 per 1000 person-years in patients with persistently low Agile 3+ scores and 30.1 per 1000 person-years in patients with persistently high Agile 3+ scores. In patients with high Agile 3+ score at baseline, a decrease in the score by more than 20% was associated with substantial reduction in the risk of LREs. A similar trend was observed for the Agile 4 score, although it missed more LREs in the low-risk group. Conclusions and Relevance: Findings of this study suggest that single or serial Agile scores are highly accurate in predicting LREs in patients with MASLD, making them suitable alternatives to liver biopsy in routine clinical practice and in phase 2b and 3 clinical trials for steatohepatitis.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Varizes Esofágicas e Gástricas , Fígado Gorduroso , Neoplasias Hepáticas , Adulto , Humanos , Masculino , Adolescente , Pessoa de Meia-Idade , Feminino , Técnicas de Imagem por Elasticidade/métodos , Estudos de Coortes , Vibração , Varizes Esofágicas e Gástricas/complicações , Varizes Esofágicas e Gástricas/patologia , Hemorragia Gastrointestinal , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Fígado Gorduroso/complicações , Fígado Gorduroso/patologia , Neoplasias Hepáticas/patologia
18.
Eur Arch Otorhinolaryngol ; 281(5): 2609-2617, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38461420

RESUMO

PURPOSE: The aim of this prospective study was to investigate the diagnostic performance of shear wave elastography (SWE) in differentiating benign and malignant thyroid nodules and their correlation with the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS). METHODS: This prospective study included 370 thyroid nodules in 308 patients aged 18-70 years. All the patients underwent B-mode ultrasound (US), Doppler examination, and SWE and were given an ACR TI-RADS risk score before fine needle aspiration biopsy (FNAB) and/or surgery. The correlation between SWE parameters and ACR TI-RADS categories was investigated statistically and compared with histopathologic results. Additionally, the diagnostic performance of SWE was evaluated to distinguish malignant and benign thyroid nodules. RESULTS: One hundred and thirty-five of the 370 thyroid nodules were malignant, and 235 nodules were benign. The mean shear wave velocity (SWV) value of the malignant nodules (3.70 ± 0.98 m/s) was statistically higher than that of the benign nodules (2.70 ± 0.37 m/s). The best cutoff value of the mean SWV for differentiating benign and malignant nodules was found to be 2.94 m/s (sensitivity 90.4%, specificity 89.9%, positive predictive value 81.3%, negative predictive value 94.1%, p < 0.001). The average score of the nodules according to the ACR TI-RADS was 3.57 ± 1.83 in benign nodules and 7.38 ± 2.69 in malignant nodules (p ≤ 0.001). CONCLUSION: This study showed that combining SWE and TI-RADS improves the specificity of TI-RADS alone in differentiating benign and malignant nodules.


Assuntos
Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Estudos Retrospectivos , Ultrassonografia/métodos , Elasticidade
19.
Dentomaxillofac Radiol ; 53(4): 248-256, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38502962

RESUMO

OBJECTIVES: Differentiation among benign salivary gland tumours, Warthin tumours (WTs), and malignant salivary gland tumours is crucial to treatment planning and predicting patient prognosis. However, differentiation of those tumours using imaging findings remains difficult. This study evaluated the usefulness of elasticity determined from diffusion-weighted image (DWI)-based virtual MR elastography (MRE) compared with conventional magnetic resonance imaging (MRI) findings in differentiating the tumours. METHODS: This study included 17 benign salivary gland tumours, 6 WTs, and 11 malignant salivary gland tumours scanned on neck MRI. The long and short diameters, T1 and T2 signal intensities, tumour margins, apparent diffusion coefficient (ADC) values, and elasticity from DWI-based virtual MRE of the tumours were evaluated. The interobserver agreement in measuring tumour elasticity and the receiver operating characteristic (ROC) curves were also assessed. RESULTS: The long and short diameters and the T1 and T2 signal intensities showed no significant difference among the 3 tumour groups. Tumour margins and the mean ADC values showed significant differences among some tumour groups. The elasticity from virtual MRE showed significant differences among all 3 tumour groups and the interobserver agreement was excellent. The area under the ROC curves of the elasticity were higher than those of tumour margins and mean ADC values. CONCLUSION: Elasticity values based on DWI-based virtual MRE of benign salivary gland tumours, WTs, and malignant salivary gland tumours were significantly different. The elasticity of WTs was the highest and that of benign tumours was the lowest. The elasticity from DWI-based virtual MRE may aid in the differential diagnosis of salivary gland tumours.


Assuntos
Adenolinfoma , Imagem de Difusão por Ressonância Magnética , Técnicas de Imagem por Elasticidade , Neoplasias das Glândulas Salivares , Humanos , Neoplasias das Glândulas Salivares/diagnóstico por imagem , Neoplasias das Glândulas Salivares/patologia , Técnicas de Imagem por Elasticidade/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Projetos Piloto , Diagnóstico Diferencial , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adenolinfoma/diagnóstico por imagem , Adenolinfoma/patologia , Adulto , Idoso de 80 Anos ou mais
20.
Aliment Pharmacol Ther ; 59(11): 1402-1412, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38497224

RESUMO

BACKGROUND AND AIMS: The European Association for the Study of the Liver introduced a clinical pathway (EASL CP) for screening significant/advanced fibrosis in people at risk of steatotic liver disease (SLD). We assessed the performance of the first-step FIB4 EASL CP in the general population across different SLD risk groups (MASLD, Met-ALD and ALD) and various age classes. METHODS: We analysed a total of 3372 individuals at risk of SLD from the 2017-2018 National Health and Nutrition Examination Survey (NHANES17-18), projected to 152.3 million U.S. adults, 300,329 from the UK Biobank (UKBB) and 57,644 from the Biobank Japan (BBJ). We assessed liver stiffness measurement (LSM) ≥8 kPa and liver-related events occurring within 3 and 10 years (3/10 year-LREs) as outcomes. We defined MASLD, MetALD, and ALD according to recent international recommendations. RESULTS: FIB4 sensitivity for LSM ≥ 8 kPa was low (27.7%), but it ranged approximately 80%-90% for 3-year LREs. Using FIB4, 22%-57% of subjects across the three cohorts were identified as candidates for vibration-controlled transient elastography (VCTE), which was mostly avoidable (positive predictive value of FIB4 ≥ 1.3 for LSM ≥ 8 kPa ranging 9.5%-13% across different SLD categories). Sensitivity for LSM ≥ 8 kPa and LREs increased with increasing alcohol intake (ALD>MetALD>MASLD) and age classes. For individuals aged ≥65 years, using the recommended age-adjusted FIB4 cut-off (≥2) substantially reduced sensitivity for LSM ≥ 8 kPa and LREs. CONCLUSIONS: The first-step FIB4 EASL CP is poorly accurate and feasible for individuals at risk of SLD in the general population. It is crucial to enhance the screening strategy with a first-step approach able to reduce unnecessary VCTEs and optimise their yield.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Técnicas de Imagem por Elasticidade/métodos , Inquéritos Nutricionais , Medição de Risco/métodos , Fígado Gorduroso , Fatores de Risco , Hepatopatia Gordurosa não Alcoólica , Programas de Rastreamento/métodos , Estados Unidos/epidemiologia , Cirrose Hepática , Sensibilidade e Especificidade , Japão/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA